Gas-G(GP)-range
Type
Infrared Gas Sensor
Conductivity Type
Infrared
Output Signal Type
Analog Type
Production Process
Integration
Material
Stainless Steel
IP Rating
IP20
Sensitivity
High
Certification
Other
Customized
Customized
Output
RS485/4-20mA/0.4-2V
Precision
5%Fs
After Sale Service
Yes
Customize
Yes
Trademark
FAD
Transport Package
Factory Sealed
Specification
65mm*35mm*20mm
Origin
China
HS Code
8542330000

Product Description

SF6 Infrared Gas Sensor IR Module FAD
G series infrared SF6 gas sensors uses non-dispersive infrared (NDIR) detection technology, with advantages of long life, low cost, intelligence, micro etc. Sensor is easy to use, with a complete gas detection, serial communication function, widely used in ventilation systems, industrial control, environmental monitoring and other industries.



SF6 Infrared Gas Sensor Features
Detecting gasSF6
Operating voltage12-24VDC
Operating currentAverage 80mA (10-120mA )
OutputRS485     Net
4-20mA   Current
0.4-2V     Voltage
Response time T90< 30s
 15s(500ml/min)
Recover time25
Measuring flow rate300-500 ml/min(pump)
Repeatability≤±2% FS
Linearity error≤±1% FS
Zero point temperature drift≤±0.1% FS/°C
Span temperature drift≤±0.1% FS/°C
Temperature-20°C -50°C
Humidity0-95%RH
Lifetime10 years
Dimension65mm*35mm*20mm
 
Selection
GasG-40GP-40RangePrecisionResolutionPower SupplyOutput
SF6SF6/G-40-1000PSF6/GP-40-1000P0-1000 ppm±3%FS1 ppm12-24VDCRS485/4-20mA/0.4-2V
SF6/G-40-2000PSF6/GP-40-2000P0-2000 ppm±3%FS1 ppm12-24VDCRS485/4-20mA/0.4-2V
SF6/G-40-3000PSF6/GP-40-3000P0-3000 ppm±3%FS1 ppm12-24VDCRS485/4-20mA/0.4-2V
 
O2 Oxygen Gas Sensor Features
All characteristics are based on conditions at 25ºC, 50% RH and 1013 hPa.
Measurement Range0 to 100 Vol.%
Expected Operating Life~ 1,000,000 Vol.% h
Sensor Lifetime< 6 years @ ambient air, depending on application
Electrical Connector3mm mono jack
Initial Output Signal13.0 to 16.5 mV @ dry ambient air
Response Time t90< 12 s
Drift< 1 % Vol. O2/month@ air, averaged across 12 months
Operating Temperature10 to 40 °C
Pressure Range700 to 1250 hPa
Linearity Error≤3@100 % O2, applied for 5 min
Zero Offset Voltage≤0.3 Vol O2@100% N2 applied for 5 min
Repeatability± 1 % Vol. O2 @ 100 Vol % O2 applied for 5 min
Influence of Humidity- 0.03 % rel. O2 reading per % RH
Recommended Load Resistor≥ 10 kOhm
Temperature CompensationNTC
Interferencesaccording to DIN EN ISO 80601-2-55
Weightapproximately 26 g
Material in Contact with MediaPA, PPS, PTFE, stainless steel

Application
Online monitoring
Site construction protection
SF6 leak alarm in electric power environment

 