Infrared Gas Sensor CO2 IR Ndir Carbon Dioxide Landfill Gas Detection
US$200.00 - 350.00 | 3 Pieces (MOQ) |
Port:
Shenzhen, China
Production Capacity:
100PCS/Month
Payment Terms:
T/T
Advanced Sensors Application Technology Co., Ltd.
Guangdong, China
Last Login Date:
May 26, 2025
Business Type:
Trading Company
Main Products:
Gas Sensor, O3, Ndir, Oxygen Sensor, Infrared Gas Sensor, Toxic Gas, Baseline Pid, IR Sensor, Photoionization Detector, Electrochemical Sensor
Find Similar Products
Product Description
Company Info
Basic Info.
Model NO.
CO2/A(G)(GP)(E)-range
Type
Infrared Gas Sensor
Conductivity Type
Infrared
Output Signal Type
Analog Type
Production Process
Integration
Material
Stainless Steel
IP Rating
IP20
Sensitivity
High
Customized
Customized
Output
RS485/4-20mA/0.4-2V
Precision
5%Fs
After Sale Service
Yes
Customize
Yes
Trademark
FAD
Transport Package
Factory Sealed
Specification
65mm*35mm*20mm
Origin
China
HS Code
8542330000
Product Description
CO2 Infrared Gas Sensor IR Module FAD
G series infrared CH4 gas sensors uses non-dispersive infrared (NDIR) detection technology, with advantages of long life, low cost, intelligence, micro and so on. Sensor is easy to use, with a complete gas detection, serial communication function, widely used in ventilation systems, industrial control, environmental monitoring and other industries.
Features
A Series Selection
G series infrared CH4 gas sensors uses non-dispersive infrared (NDIR) detection technology, with advantages of long life, low cost, intelligence, micro and so on. Sensor is easy to use, with a complete gas detection, serial communication function, widely used in ventilation systems, industrial control, environmental monitoring and other industries.
Features
Detecting gas | CO2 |
Operating voltage | 12-24VDC |
Operating current | Average 80mA (10-120mA ) |
Output | TTL(depends on specified model) RS485 4-20mA Current 0.4-2V Voltage |
Response time | <5s |
T90 | 15s(500ml/min) |
Recover time | 25 |
Measuring flow rate | 300-500 ml/min(pump) |
Repeatability | ≤±2% FS |
Linearity error | ≤±1% FS |
Zero point temperature drift | ≤±0.1% FS/°C |
Span temperature drift | ≤±0.1% FS/°C |
Temperature | -20°C -50°C |
Humidity | 0-95%RH |
Lifetime | 10 years |
Dimension | 65mm*35mm*20mm |
A Series Selection
Series | A-1 | Range | Precision | Resolution | Power Supply | Output |
A | CO2/A-1 | 0-1 Vol.% | ± 5% FS | 0.001% VOL | 5.5 VDC | Voltage/ TTL digital |
E Series Selection
Series | E-40 | Range | Precision | Resolution | Power Supply | Output |
E | CO2/E-40-2000P | 0-2000 ppm | 50± 5% FS | 1 ppm | 5.5 VDC | Voltage/ TTL digital |
CO2/ E-40-5000P | 0-5000 ppm | 50± 5% FS | 2 ppm | 5.5 VDC | Voltage/ TTL digital | |
CO2/ E-40-1 | 0-1 Vol.% | ± 5% FS | 0.001% VOL | 5.5 VDC | Voltage/ TTL digital |
G Series Selection
Series | G-40 | GP-40 | Range | Precision | Resolution | Power Supply | Output |
G | CO2/G-40-1000p | CO2/GP-40-1000p | 0-1000 ppm | ±5%FS | 1 ppm | 12-24VDC | RS485/4-20mA/0.4-2V |
CO2/G-40-2000p | CO2/GP-40-2000p | 0-2000 ppm | ±5%FS | 1 ppm | 12-24VDC | RS485/4-20mA/0.4-2V | |
CO2/G-40-5000p | CO2/GP-40-5000p | 0-5000 ppm | ±5%FS | 2 pmm | 12-24VDC | RS485/4-20mA/0.4-2V | |
CO2/G-40-10000p | CO2/GP-40-10000p | 0-10000 ppm | ±5%FS | 5 ppm | 12-24VDC | RS485/4-20mA/0.4-2V |
Application
Dynamic Environments: Telecommunication equipment room, electrical power equipment room and stations
Building Automatic Control: Hotel, office building, museum and ventilation system of buildings
Industrial Work Field: Occupational safety, warehouse, medicine and ventilation system of workshop production line
Public Occasion: Airport, railway station, high speed railway, shopping center and hospital
School Life: Dormitory, office, classroom, library and indoor competition field
Transporting Storage: Food preservation and transportation, warehouse, food and vegetable preserving storage
Agricultural Cultivation: Conservatory, vegetable greenhouse, flowers and plants greenhouse, modern hydroponics garden
Dynamic Environments: Telecommunication equipment room, electrical power equipment room and stations
Building Automatic Control: Hotel, office building, museum and ventilation system of buildings
Industrial Work Field: Occupational safety, warehouse, medicine and ventilation system of workshop production line
Public Occasion: Airport, railway station, high speed railway, shopping center and hospital
School Life: Dormitory, office, classroom, library and indoor competition field
Transporting Storage: Food preservation and transportation, warehouse, food and vegetable preserving storage
Agricultural Cultivation: Conservatory, vegetable greenhouse, flowers and plants greenhouse, modern hydroponics garden