Infrared Gas Sensor Ndir Biogas Landfill Incinerator PCB CH4 CO2 Co Sf6
US$200.00 - 350.00 | 3 Pieces (MOQ) |
Port:
Shenzhen, China
Production Capacity:
100PCS/Month
Payment Terms:
T/T
Advanced Sensors Application Technology Co., Ltd.
Guangdong, China
Last Login Date:
May 26, 2025
Business Type:
Trading Company
Main Products:
Gas Sensor, O3, Ndir, Oxygen Sensor, Infrared Gas Sensor, Toxic Gas, Baseline Pid, IR Sensor, Photoionization Detector, Electrochemical Sensor
Find Similar Products
Product Description
Company Info
Basic Info.
Model NO.
Gas-range
Type
Infrared Gas Sensor
Conductivity Type
Output Signal Type
Analog Type
Production Process
Integration
Material
Stainless Steel
IP Rating
IP20
Sensitivity
High
Customized
Customized
Output
RS485/4-20mA/0.4-2V
Precision
5%Fs
After Sale Service
Yes
Customize
Yes
Trademark
FAD
Transport Package
Factory Sealed
Specification
65mm*35mm*20mm
Origin
China
HS Code
8542330000
Product Description
FAD NDIR Infrared Gas Sensor Module
G series infrared gas sensor uses non-dispersive infrared (NDIR) detection technology, with good advantages of long life, low cost, intelligence, micro and so on. Sensor is easy to use, with a complete gas detection, serial communication function, widely used in ventilation systems, industrial control, environmental monitoring and other industries.
Product Selection
Application
Mining
Coal processing
Natural gas
Pipeline gas leaks
Petroleum extraction
Petrochemical
Pipeline leak detection
Process control analysis
Biogas engineering
Waste incineration and landfill
Municipal engineering
Fire rescue site
G series infrared gas sensor uses non-dispersive infrared (NDIR) detection technology, with good advantages of long life, low cost, intelligence, micro and so on. Sensor is easy to use, with a complete gas detection, serial communication function, widely used in ventilation systems, industrial control, environmental monitoring and other industries.
Product Selection
Gas | GP-40 | Range | Precision | Resolution | Power supply | Output |
CH4 | CH4/GP-40-5 | 0-5VOL% | ±5%FS | 0.01 VOL % | 12-24VDC | RS485/4-20mA/0.4-2V |
CH4/GP-40-10 | 0-10VOL% | ±5%FS | 0.01 VOL % | 12-24VDC | RS485/4-20mA/0.4-2V | |
CH4/GP-40-20 | 0-20VOL% | ±5%FS | 0.01 VOL % | 12-24VDC | RS485/4-20mA/0.4-2V | |
CH4/GP-40-50 | 0-50VOL% | ±5%FS | 0.01 VOL % | 12-24VDC | RS485/4-20mA/0.4-2V | |
CH4/GP-40-100 | 0-100VOL% | ±5%FS | 0.1 VOL % | 12-24VDC | RS485/4-20mA/0.4-2V |
Detection principle | NDIR |
Detection gas | CH4 |
Detection Range | 0-5VOL, 0-10Vol%, 0-20Vol%, 0-50Vol%, 0-100Vol% |
Resolution | 0-5Vol%, 0-10Vol%, 0-20Vol%, 0-50Vol% Resolution is 0.01Vol% 0-100Vol% Resolution is 0.1Vol% |
Precision | ±5%FS |
Operation Voltage | 12-24VDC |
Operation Current | 10-120mA |
Output Mode | RS485( baud rate 9600) |
Response Time | T90<30s |
Temperature | -20°C -50°C |
Humidity | 0-95%RH |
Operating life | >10Years |
Gas | Model | Range | Precision | Resolution |
CO2 | CO2/G(P)-40-1000P | 0-1000 ppm | ±5%FS | 1 ppm |
CO2/G(P)-40-2000P | 0-2000 ppm | ±5%FS | 1 ppm | |
CO2/G(P)-40-5000P | 0-5000 ppm | ±5%FS | 2 ppm | |
CO2/G(P)-40-10000P | 0-1Vol% | ±5%FS | 5 ppm |
Detection principle | NDIR |
Detection gas | CO2 |
Detection Range | 0-1000ppm, 0-2000ppm, 0-5000ppm, 0-1Vol%, 0-5Vol% |
Resolution | 0-1000ppm, 0-2000ppm, 0-5000ppm resolution is 1ppm 0-1Vol% resolution is 0.001VOL% |
Detection precision | ±5%FS |
Operation Voltage | 12-24VDC |
Operation current | 10-120mA |
Output Mode | RS485(baud rate 9600) |
Response Time | T90<30s |
Temperature | -20°C -50°C |
Humidity | 0-95%RH |
Operation Life | >10 years |
Sensor Measurement | 65mm*35mm*20mm |
Gas | Model | Range | Precision | Resolution |
CO | CO/G(P)-40-5 | 0-5Vol% | ±5%FS | 0.01 Vol% |
CO/G(P)-40-10 | 0-10Vol% | ±5%FS | 0.01 Vol% | |
CO/G(P)-40-20 | 0-20Vol% | ±5%FS | 0.01 Vol% | |
CO/G(P)-40-50 | 0-50Vol% | ±5%FS | 0.01 Vol% | |
CO/G(P)-40-100 | 0-100Vol% | ±5%FS | 0.1 Vol% |
Detection Principle | NDIR |
Detection gas | CO |
Detection Range | 0-5Vol%, 0-10Vol%, 0-20Vol%, 0-50Vol%, 0-100Vol% |
Resolution | 0-5Vol%,0-10Vol% resolution is 1ppm 0-20Vol%, 0-50Vol% resolution is 0.01Vol% 0-100Vol% resolution is 0.1Vol% |
precision | ±5%FS |
Operation Voltage | 12-24VDC |
Operation current | 10-120mA |
Output Mode | RS485(baud rate 9600) |
Response Time | T90<30s |
Temperature | -20°C -50°C |
Humidity | 0-95%RH |
Operation Life | >10 years |
Sensor Measurement | 65mm*35mm*20mm |
Gas | Model | Range | Precision | Resolution |
SF6 | SF6/G(P)-40-1000P | 0-1000 ppm | ±3%FS | 1 ppm |
SF6/G(P)-40-2000P | 0-2000 ppm | ±2%FS | 1 ppm | |
SF6/G(P)-40-3000P | 0-3000 ppm | ±2%FS | 1 ppm |
Detection Principle | NDIR |
Detection gas | SF6 |
Detection Range | 0-1000ppm,0-2000ppm,0-3000ppm |
Resolution | 0-1000ppm,0-2000ppm,0-3000ppm resolution is 1ppm |
precision | ±3%FS |
Operation Voltage | 12-24VDC |
Operation current | 10-120mA |
Output Mode | RS485(baud rate 9600),4-20mA,0.4-2V |
Response Time | T90<30s |
Temperature | -20°C -50°C |
Humidity | 0-95%RH |
Operation Life | >10 years |
Application
Mining
Coal processing
Natural gas
Pipeline gas leaks
Petroleum extraction
Petrochemical
Pipeline leak detection
Process control analysis
Biogas engineering
Waste incineration and landfill
Municipal engineering
Fire rescue site
Send your message to this supplier