消息
×
loading..
x
  • ITG O2 Oxygen Sensor Industrial Sensor 0-25 Vol% O2/I-08
  • ITG O2 Oxygen Sensor Industrial Sensor 0-25 Vol% O2/I-08
  • ITG O2 Oxygen Sensor Industrial Sensor 0-25 Vol% O2/I-08
  • ITG O2 Oxygen Sensor Industrial Sensor 0-25 Vol% O2/I-08
  • ITG O2 Oxygen Sensor Industrial Sensor 0-25 Vol% O2/I-08
  • ITG O2 Oxygen Sensor Industrial Sensor 0-25 Vol% O2/I-08

ITG O2 Oxygen Sensor Industrial Sensor 0-25 Vol% O2/I-08

US$12.00-120.00 1 Piece (MOQ)
Port:
Shenzhen, China
Production Capacity:
1000PCS/Month
Payment Terms:
T/T

Last Login Date:

May 26, 2025

Business Type:

Trading Company

Main Products:

Gas Sensor, O3, Ndir, Oxygen Sensor, Infrared Gas Sensor, Toxic Gas, Baseline Pid, IR Sensor, Photoionization Detector, Electrochemical Sensor

Find Similar Products

Product Description

Company Info

Basic Info.

Model NO.
O2/I-08
Type
Electrochemical Gas Sensor
Conductivity Type
Volume Control Type
Output Signal Type
Production Process
Material
PA, PPS, PTFE, Stainless Steel
IP Rating
IP20
Sensitivity
Certification
RoHS
Customized
Output
TTL/4-20mA/RS485
Transmitter Board
Integrated/Seperated
Wire
Two or Three Wire
Detecting Range
Selectable
After Sale Service
Yes
Trademark
ITG
Transport Package
Factory Sealed
Specification
Max29.2*41.4
Origin
Germany
HS Code
9027100090

Product Description

ITG O2 - Industrial Sensor / Type I-08

Galvanic gas sensor with high output voltage, designed to be used for high resolutions between 0 and 25 Vol.% O2.

All characteristics are based on conditions at 25°C, 50% RH and 1013 hPa

 
Key Feature
Measurement Range0 to 25 Vol.%
Expected Operating Life~ 500,000 Vol.% h
Sensor Lifetime< 3 years @ ambient air
Electrical Connector3-pin Molex®
Gas ConnectorM16x1 Thread
Initial Output Signal70.0 to 90.0 mV @ dry ambient air
Response Time t90<5s
Drift<10 % per year
Operating Temperature0 to 50ºC
Pressure Range700 to 1250 hPa
Linearity Error0 to 2 Vol.% O2: ± 0.1 absolute
2.1 to 35 Vol.% O2: ± 0.5 relative
Temperature CompensationNTC
Recommended Load Resistor≥ 10 kOhm
Influence of Humidity- 0.03 % rel. O2 reading per % RH
Interferences< 0.1 %O2 response to:    
12.0 Vol.% CO2, balance N2         1,000 ppm Benzene, balance N2
1.5% CH4, alternating with air     1,900 ppm NO, balance N2  
1,000 ppm CO, balance N2  
Weightapproximately 25 g
Material in Contact with MediaPA,  PPS, PTFE, stainless steel

Storage Condition
Temperature Rangerecommended:  5 to 30 °C
maximum:  -20 to 50 °C
Humidityup to 100 % RH
Shelf Life< 3 months recommended
Ambient Pressure600 to 1750 hPa


Oxygen Module Parameters
Module typeGM-I2(3)-M/C/S-**-****/G/P/F/FL
Detected gasToxic gas
Detecting principleElectrochemistry
SamplingDiffusing  pump  flange  thread
Responding time30s~40s(of the sensor)
Module accuracy≤±3%FS(actual concentration, higher accuracy depends on specified sensors)
Module repeatability≤±2% FS
Module linear error≤±2% FS
Module zero temperature drift≤±2% (FS/year)
Module operating temperature-40~80°C
Module humidity0-95%RH(non-condensation)
Sensor operating temperature-20°C~50°C
Sensor humidity0-90%RH(non-condensation)
Signal outputTTL/4-20mA /RS485   (two or three wire)
Transmitting distance1000 meters(RS485)
Operating voltageDC 12-36V
Maximum power≤0.8W
Size80*48mm
Explosion proofIntrinsic safe
Connection cableRVVP3 x 1.5mm²

Oxygen Module Applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control