• Carbon Monoxide CO Gas Sensor Environmental Air Quality Monitoring Compact
  • Carbon Monoxide CO Gas Sensor Environmental Air Quality Monitoring Compact
  • Carbon Monoxide CO Gas Sensor Environmental Air Quality Monitoring Compact
  • Carbon Monoxide CO Gas Sensor Environmental Air Quality Monitoring Compact
  • Carbon Monoxide CO Gas Sensor Environmental Air Quality Monitoring Compact
  • Carbon Monoxide CO Gas Sensor Environmental Air Quality Monitoring Compact

Carbon Monoxide CO Gas Sensor Environmental Air Quality Monitoring Compact

US$200.00-350.00 3 Pieces (MOQ)
Port:
Shenzhen, China
Production Capacity:
1000PCS/Month
Payment Terms:
T/T

Last Login Date:

May 26, 2025

Business Type:

Trading Company

Main Products:

Gas Sensor, O3, Ndir, Oxygen Sensor, Infrared Gas Sensor, Toxic Gas, Baseline Pid, IR Sensor, Photoionization Detector, Electrochemical Sensor

Find Similar Products

Product Description

Company Info

Basic Info.

Model NO.
CO/C(F)(A)-****
Type
Electrochemical Gas Sensor
Conductivity Type
Volume Control Type
Output Signal Type
Analog Type
Production Process
Integration
Material
PC
IP Rating
IP20
Sensitivity
High
Certification
RoHS
Customized
Customized
Output
TTL/4-20mA/RS485
Transmitter Board
Integrated/Seperated
Wire
Two or Three Wire
Detecting Range
Selectable
After Sale Service
Yes
Trademark
FAD
Transport Package
Transparent Plastic Box
Specification
32mm
Origin
China
HS Code
8542330000

Product Description

Gas Module Introduction
FAD gas module with two/three wire TTL/0-20mA/RS485 output, integrates toxic gas sensor + transmitter board. Adopting imported advanced electrochemical gas sensors, it has features of high accuracy, long lifetime, high stability and high anti-interference. The module is designed to prevent circuit reversed connection, high voltage, high current and lightning.
 
Gas Module Feature
- Long lifetime imported advanced electrochemical sensors
- High accuracy op ams, power supply IC, stable and sensitive
- Detect low or high concentration toxic gases precisely
- High anti-interference ability
- Over range protection, reversed polarity protection and lightning protection
- Low power consumption with a standard 4-20mA two/three-wire signal output
- Interface: pump, diffusing, flange, flange thread types
- 12-36VDC operating voltage




Sensor Detecting Range Selection
Detecting range (ppm)Output signal (nA/ppm)Features
CO/C-1000 100.00 ± 20.00  
CO/C-200 900.00 ± 150.00 highly sensitive
CO/CF-1000 100.00 ± 20.00 with filter
CO/CF-10000-4E 15.00 ± 4.00 Hydrogen compensated
CO/CF-200 700.00 ± 120.00 highly sensitive, with filter
CO/CF-2000 50.00 ± 10.00 Emission Monitoring
CO/CF-2000-4E 80.00 ± 25.00 Hydrogen compensated
CO/CF-200-4E 470.00 ± 120.00 Hydrogen compensated
CO/CF-4000 30.00 ± 6.00 Emission Monitoring
CO/CF-40000 6.00 ± 2.00 Emission Monitoring
CO/CF-500 200.00 ± 40.00 with filter
CO/CFA-1000 100.00 ± 20.00 highly selective
CO/CFA-10000 15.00 ± 4.00 highly selective
CO/CFA-200 550.00 ± 150.00 highly selective
CO/CFA-500 160.00 ± 30.00 highly selective
CO/CFA-5000 30.00 ± 5.00 highly selective

Sensor Performance Characteristics(take CO/CF-200 as an example)
Nominal Range0 - 100 ppm
Maximum Overload200 ppm
Expected Operation Life2 years in air
Output Signal90 ±18 nA/ppm
Resolution1 ppm
Temperature Range- 10 °C to 40 °C
Pressure RangeAtmospheric 1)
Pressure CoefficientNo data
T90 Response Time< 50 sec
Relative Humidity Range15 % to 90 % R.H. non-condensing
Baseline0 ppm ±4 ppm
Maximum Zero Shift(+20°C to +40°C) -8 ppm
Typical Long Term Output Drift< 5% per 6 months
Recommended Load Resistor10 Ohm
Bias VoltageNot allowed
Repeatability< 3 % of signal
Output Linearity< 5 % full scale
Humidity Effect 2)< 4 ppm
1) no data for deviations
2) abrupt changes in rel. humidity causes a short term transient signal

 
Sensor Physical Characteristics
Weight~ 13 g
Position SensitivityNone
Storage LifeSix months in container
Recommended Storage Temperature5 °C - 20 °C
Warranty Period12 months from date of dispatch




Module Parameters
Module typeGM-I2(3)-M/C/S-**-****/G/P/F/FL
Detected gasToxic gas
Detecting principleElectrochemistry
SamplingDiffusing  pump  flange  thread
Responding time30s~40s(of the sensor)
Module accuracy≤±3%FS(actual concentration, higher accuracy depends on specified sensors)
Module repeatability≤±2% FS
Module linear error≤±2% FS
Module zero temperature drift≤±2% (FS/year)
Module operating temperature-40~80°C
Module humidity0-95%RH(non-condensation)
Sensor operating temperature-20°C~50°C
Sensor humidity0-90%RH(non-condensation)
Signal outputTTL/4-20mA /RS485   (two or three wire)
Transmitting distance1000 meters(RS485)
Operating voltageDC 12-36V
Maximum power≤0.8W
Size80*48mm
Explosion proofIntrinsic safe
Connection cableRVVP3 x 1.5mm²

Module applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control


 
Send your message to this supplier
Mr. Luke Li

Post a Sourcing Request Now

People who liked this also liked
Get Quick Quotes