Basic Info.
Model NO.
Gas-range
Type
Electrochemical Gas Sensor
Conductivity Type
Volume Control Type
Output Signal Type
Analog Type
Production Process
Integration
Material
PC
IP Rating
IP20
Sensitivity
High
Certification
RoHS
Customized
Customized
Output
Ttl/4-20mA/RS485
Transmitter Board
Integrated/Seperated
Wire
Two or Three Wire
Detecting Range
Selectable
After Sale Service
Yes
Trademark
FAD
Transport Package
Transparent Plastic Box
Specification
20-41mm(single sensor)
Origin
China
HS Code
8542330000
Product Description
Gas Module Introduction
FAD gas module with two/three wire TTL/0-20mA/RS485 output, integrates toxic gas sensor + transmitter board. Adopting imported advanced electrochemical gas sensors, it has features of high accuracy, long lifetime, high stability and high anti-interference. The module is designed to prevent circuit reversed connection, high voltage, high current and lightning
Cl2 Detecting Range Selection
Alc Sensor Detecting Range Selection
H2 Sensor Detecting Range Selection
H2O2 Sensor Detecting Range Selection
HCl Sensor Detecting Range Selection
HCN Sensor Detecting Range Selection
O2 Sensor Detecting Range Selection
PH3 Sensor Detecting Range Selection
NO2 Sensor Detecting Range Selection
CH2O Sensor Detecting Range Selection
SiH4Sensor Detecting Range Selection
SO2 Sensor Detecting Range Selection
H2S Sensor Detecting Range Selection
C2H4 Sensor Detecting Range Selection
ETO Sensor Detecting Range Selection
CO Sensor Detecting Range Selection
NO Sensor Detecting Range Selection
NH3 Sensor Detecting Range Selection
Module Parameters
Module applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control
FAD gas module with two/three wire TTL/0-20mA/RS485 output, integrates toxic gas sensor + transmitter board. Adopting imported advanced electrochemical gas sensors, it has features of high accuracy, long lifetime, high stability and high anti-interference. The module is designed to prevent circuit reversed connection, high voltage, high current and lightning
Gas Module Feature
- Long lifetime imported advanced electrochemical sensors- High accuracy op ams, power supply IC, stable and sensitive
- Detect low or high concentration toxic gases precisely
- High anti-interference ability
- Over range protection, reversed polarity protection and lightning protection
- Low power consumption with a standard 4-20mA two/three-wire signal output
- Interface: pump, diffusing, flange, flange thread types
- 12-36VDC operating voltage
O3 Sensor Detecting Range Selection
O3 Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-5 | O3/M-5 | O3/C-5 | O3/S-5-S | |
0-100 | O3/M-100 | O3/C-100 | ||
0-200 | O3/C-200 | |||
0-1000 | O3/C-1000 | |||
0-5000 | O3/C-5000 | |||
0-30000 | O3/S-30000 |
Cl2 Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-20 | Cl2/M-20 | Cl2/C-20 | Cl2/S-20-S | Cl2/S-20 |
0-50 | Cl2/S-50-S | Cl2/S-50 | ||
0-200 | Cl2/M-200 | Cl2/C-200 | Cl2/S-200-S | Cl2/S-200 |
0-2000 | Cl2/C-2000 | |||
0-5000 | Cl2/C-5000 |
Alc Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact |
0-100 | Alc/C-100 | |
0-200 | Alc/M-200 |
H2 Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-1000 | H2/M-1000 | H2/CA-1000 H2/CB-1000 | H2/SA-1000-S | H2/SA-1000 |
0-2000 | H2/C-2000 | H2/S-2000-S | H2/S-2000 | |
0-4000 | H2/M-4000 | |||
0-5000 | H2/C-5000 | |||
0-10000 | H2/CT-10000 | H2/S-10000-S | ||
0-20000 | H2/C-20000 | H2/SA-20000-S | ||
0-40000 | H2/M-40000 | H2/C-40000 H2/CT-40000 |
H2O2 Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact |
0-100 | H2O2/MB-100 | H2O2/CB-100 |
0-500 | H2O2/MB-500 | H2O2/CB-500 |
0-2000 | H2O2/CB-2000 |
HCl Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact |
0-20 ppm | HCl/M-20 | HCl/C-20 |
0-20 ppm | HCl/M-200 | HCl/C-200 |
0-1000 ppm | HCl/C-1000 | |
0-3000 ppm | HCl/C-3000 |
HCN Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-50 ppm | HCN/M-50 | |||
0-100 ppm | HCN/M-100 | HCN/C-100 | HCN/S-100-S | HCN/S-100 |
O2 Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-50 ppm | HCN/M-50 | |||
0-100 ppm | HCN/M-100 | HCN/C-100 | HCN/S-100-S | HCN/S-100 |
PH3 Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-5 ppm | PH3/M-5 | PH3/C-5 | PH3/S-5-S | PH3/S-5 |
0-20 ppm | PH3/M-20 | |||
0-200 ppm | PH3/M-200 | |||
0-500 ppm | PH3/C-500 | |||
0-1000 ppm | PH3/C-1000 | |||
0-2000 ppm | PH3/M-2000 | PH3/C-2000 | ||
0-4000 ppm | PH3/C-4000 |
NO2 Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-1 ppm | NO2/C-1 | |||
0-20 ppm | NO2/M-20 | NO2/C-20 | NO2/S-20-S | |
0-100 ppm | NO2/M-100 | NO2/S-100 | ||
0-500 ppm | NO2/M-500 | NO2/C-500 | NO2/S-500-S | |
0-1000 ppm | NO2/S-1000-S | NO2/S-1000 | ||
0-2000 ppm | NO2/S-2000-S | |||
0-5000 ppm | NO2/S-5000-S |
CH2O Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-10 | CH2O/M-10 CH2O/M-10-2E | CH2O/C-10 | CH2O/C-10 | |
0-50 | CH2O/M-50 | |||
0-1000 | CH2O/M-1000 | CH2O/C-1000 |
SiH4Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-50 ppm | SiH4/M-50 | SiH4/C-50 | SiH4/S-50-S | SiH4/S-50 |
SO2 Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-1 | SO2/C-1 | |||
0-20 | SO2/M-20 SO2-M-2E SO2/MF-20 | SO2/C-20 SO2/CF-20 | SO2/S-20-S | SO2/S-20 |
0-100 | SO2/M-100-2E SO2/MF-100 | SO2/C-100 SO2/CF-100 | SO2/SF-100-S | SO2/S-20 SO2/SF-20 |
0-200 | SO2/MF-200 | |||
0-400 | SO2/SF-400-S | |||
0-1000 | SO2/MF-1000 | |||
0-2000 | SO2/MF-2000 | SO2/C-2000 SO/CF-2000 | SO2/S-2000-S SO2/SF-2000-S | |
0-10000 | SO2/MF-10000 | SO2/CF-10000 | SO2/SF-10000-S |
H2S Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-10 ppm | H2S/C-10 | H2S/S-50 H2S/SP-50 | ||
0-50 ppm | H2S/M-50 | H2S/C-50 | H2S/S-50-S | |
0-100 ppm | H2S/M-100 | H2S/CG-100-4E H2S/CP-100 | ||
0-200 ppm | H2S/M-200-2E | H2S/C-200 | H2S/SG-200-S | H2S/S-200 |
0-500 ppm | H2S/M-500 | H2S/C-500 H2S/CP-500 | ||
0-1000 ppm | H2S/C-1000 | H2S/S-1000 H2S/SP-1000 | ||
0-2000 ppm | H2S/M-2000 | H2S/C-2000 H2S/CG-2000 H2S/CP-2000 | H2S/SG-2000-S | |
0-5000 ppm | H2S/C-5000 H2S/CP-5000 | H2S/S-5000 | ||
0-10000 ppm | H2S/CP-10000 | H2S/S-10000-S | H2S/S-10000 H2S/SP-10000 |
C2H4 Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-10 | C2H4/M-10 | C2H4/C-10 | C2H4/S-10-S | C2H4/S-10 |
0-200 | C2H4/M-200 | C2H4/C-200 | C2H4/S-200-S | C2H4/S-200 |
0-1500 | C2H4/M-1500 | C2H4/C-1500 | C2H4/S-1500-S | C2H4/S-1500 |
ETO Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact |
0-10 | ETO/M-10 | |
0-20 | ETO/M-20 | ETO/C-20 |
0-100 | ETO/M-100 | ETO/C-100 |
0-500 | ETO/M-500 | |
0-1000 | ETO/M-1000 | ETO/C-1000 |
0-50000 | ETO/C-5000 |
CO Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-200 | CO/MF-200 | CO/C-200 CO/CF-200 CO/CF-200-4E CO/CFA-200 | CO/SF-200-S CO/SF-200-4E-S CO/SFA-200-S | CO/SF-200 CO/SF-SFA-200 |
0-500 | CO/MF-500 CO/MFA-500 | CO/CF-500 CO/CFA-500 | CO/SF-500-S | CO/SF-500 |
0-1000 | CO/MF-1000 | CO/C-1000 CO/CF-1000 CO/CFA-1000 | CO/S-1000-S CO/SF-1000-S CO/SFA-1000-S | CO/S-1000 CO/SF-1000 CO/SFA-1000 |
0-2000 | CO/MF-2000 | CO/CF-2000 CO/CF-2000-4E | CO/SF-2000-S CO/SF-2000-4E-S CO/SGF-2000-4E-S | CO/SF-2000 |
0-4000 | CO/CF-4000 | CO/SF-4000-S | CO/SF-4000 | |
0-5000 | CO/CFA-5000 | |||
0-10000 | CO/CF-10000-4E CO/CFA-10000 | CO/SF-10000-4E-S CO/SFA-10000-4E-S | CO/SFA-10000 | |
0-40000 | CO/CF-40000 | CO/SF-40000-S |
NO Sensor Detecting Range Selection
Detecting range (ppm)/Size | Miniature | Compact | Slim | Standard |
0-1 | NO/C-1 | |||
0-25 | NO/M-25 | NO/C-25 | NO/S-25-S | NO/S-25 |
0-100 | NO/C-100 NO/CF-100 | NO/S-100-S NO/SF-100-S | NO/S-100 NO/SF-100 | |
0-200 | NO/SF-200-S | |||
0-250 | NO/M-250 | |||
0-1000 | NO/M-1000 | NO/SF-1000-S | NO/S-1000 | |
0-2000 | NO/CF-2000 | NO/SGF-2000-S | ||
0-5000 | NO/SF-5000-S | NO/S-5000 |
NH3 Sensor Detecting Range Selection
Detecting range(ppm)/Size | Miniature | Compact | Slim | Standard |
0-50 | NH3/CR-50 | |||
0-100 | NH3/MR-100 NH3/MR-100-2E | |||
0-200 | NH3/CR-200 | NH3/SR-200-S | NH3/SR-200 | |
0-500 | NH3/MR-500 | |||
0-1000 | NH3/MR-1000 NH3/MR-1000-2E | NH3/CR-1000 | NH3/SR-1000-S | NH3/SR-1000 |
0-2000 | NH3/MR-2000 | |||
0-5000 | NH3/MR-5000 | NH3/CR-5000 | ||
0-10000 | NH3/MR-10000 | NH3/CR-10000 |
Module Parameters
Module type | GM-I2(3)-M/C/S-**-****/G/P/F/FL |
Detected gas | Toxic gas |
Detecting principle | Electrochemistry |
Sampling | Diffusing pump flange thread |
Responding time | 30s~40s(of the sensor) |
Module accuracy | ≤±3%FS(actual concentration, higher accuracy depends on specified sensors) |
Module repeatability | ≤±2% FS |
Module linear error | ≤±2% FS |
Module zero temperature drift | ≤±2% (FS/year) |
Module operating temperature | -40~80°C |
Module humidity | 0-95%RH(non-condensation) |
Sensor operating temperature | -20°C~50°C |
Sensor humidity | 0-90%RH(non-condensation) |
Signal output | TTL/4-20mA /RS485 (two or three wire) |
Transmitting distance | 1000 meters(RS485) |
Operating voltage | DC 12-36V |
Maximum power | ≤0.8W |
Size | 80*48mm |
Explosion proof | Intrinsic safe |
Connection cable | RVVP3 x 1.5mm² |
Module applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control